About this product
Engineered for elite CBRN (Chemical, Biological, Radiological, Nuclear) protection, the MIRA Safety NC-11 Gloves deliver 24-hour defense against vaporized chemical warfare agents, biological contaminants, and nuclear fallout particles. Rigorously validated by military and industrial testing protocols, these gloves are the benchmark for hazmat hand protection in extreme scenarios.
Core Protective Capabilities
- 24-Hour CWA Resistance: Proven protection against vaporized chemical warfare agents (CWAs) like Mustard Gas (HD), meeting DEF STAN 93-55/2 & QSTAG 991 standards.
- Impermeable Barrier: Blocks biological pathogens (viruses, bacteria) and radioactive particulates (nuclear fallout).
- Extended Wear Durability: Maintains chemical resistance and flexibility for up to 30 days of continuous use without degradation.
- Broad-Spectrum Chemical Defense: Superior resistance to hazardous liquid chemical splashes and permeation (ASTM F739 tested).
Tactical Mobility & Integration Features
- Enhanced Dexterity: Ambidextrous design with corrugated joints, textured palms/fingertips for a secure grip on firearms, tools, and equipment.
- Secure Sealing: Extra-long cuffs enable reliable integration with hazmat suits using Kappler ChemTape® to seal glove-to-sleeve junctions.
- Snug, Slip-Resistant Fit: Ergonomically designed to prevent slippage during critical operations.
- Rapid Decontamination: Smooth exterior finish allows for efficient chemical decon procedures.
Engineered for Longevity & Reliability
- Premium Butyl Rubber Construction: Industry-standard material for high-performance CBRN/Hazmat gloves, offering unmatched permeation resistance.
- Exceptional Shelf Life: 15-year shelf life when stored in original packaging within optimal conditions (41°F - 77°F / 5°C - 25°C, <75% humidity, dark environment). Withstands temporary extremes (−58°F to 140°F / −50°C to 60°C).
- Comfort & Safety: Dusted with non-irritating, non-toxic mineral powder lining.
- Comprehensive Durability: Resists abrasion, puncture, tearing, and low-temperature stiffening (EN 388; ASTM D412, D624, D1053, F1342).
Rigorous Compliance & Testing
MIRA Safety NC-11 Gloves meet or exceed the most demanding global standards for CBRN personal protective equipment (PPE):
- Chemical & Biological Resistance: EN 374-1/2/3; DEF STAN 93-55/2 (Annex A & B); QSTAG 991; TOP 8-2-501; TOP 10-2-022.
- Tactical Durability: EN 388 (Abrasion/Cut/Puncture/Tear); ASTM F1342 (Puncture); ASTM F1790 (Cut).
- Safety & Performance: EN 420 (General Glove Requirements); EN 1149-1 (Electrostatic properties).
- Material Integrity: ASTM D412 (Tensile Strength); ASTM D2240 (Durometer Hardness); ASTM D624 (Tear Strength); ASTM D1053 (Low-Temp Stiffening).
- Electrostatic Decay: FTMS 191A Method 5931 (Electrostatic Decay of Fabrics).
Global Compliance: Meets EEC Directive 89/686/EEC for PPE.
Precise Sizing for Optimal Protection
| Order Size | XS | S | M | L | XL | XXL |
|---|---|---|---|---|---|---|
| Mold Size | XS | SM | MD | LG | XL | XXL |
| Middle Finger Length | 2.95" / 7.5 cm | 3.15" / 8.0 cm | 3.35" / 8.5 cm | 3.54" / 9.0 cm | 3.74" / 9.5 cm | 3.94" / 10.0 cm |
| Palm Width | 3.74" / 9.5 cm | 3.86" / 9.8 cm | 3.98" / 10.1 cm | 4.09" / 10.4 cm | 4.21" / 10.7 cm | 4.33" / 11.0 cm |
| Glove Length | 13.58" / 34.5 cm | 13.78" / 35.0 cm | 13.98" / 35.5 cm | 14.17" / 36.0 cm | 14.37" / 36.5 cm | 14.57" / 37.0 cm |
| Wrist Circumference | 13.07" / 33.2 cm | 13.15" / 33.4 cm | 13.23" / 33.6 cm | 13.39" / 34.0 cm | 13.54" / 34.4 cm | 13.70" / 34.8 cm |
| Pair Weight | 0.46 lb / 0.21 kg | 0.46 lb / 0.21 kg | 0.49 lb / 0.22 kg | 0.51 lb / 0.23 kg | 0.53 lb / 0.24 kg | 0.55 lb / 0.25 kg |
Trusted by Professionals Worldwide
The NC-11 is the essential hand protection component for military units, law enforcement agencies, HAZMAT teams, and preparedness-minded civilians requiring certified, long-duration CBRN defense. Its unmatched combination of extended protection, tactical dexterity, and 15-year shelf stability delivers critical operational readiness and value.
Care, Inspection & Storage
- Inspection: Examine gloves for integrity before and after each use, paying particular attention to flexion points (finger joints, knuckles, wrist). Replace if any cracking, hardening, or damage is observed.
- Storage: Store in original packaging in a cool, dark, dry environment at 41°F–77°F (5°C–25°C) with <75% RH. Can tolerate temporary extremes of −58°F to 140°F (−50°C to 60°C).
- Shelf Life: Up to 15 years under proper storage conditions.
Deployed by:
The United States
DEFENSE
The United States
HOMELAND SECURITY
The United States
BORDER PROTECTION
The United States
GUARD
The United States
CORRECTIONS
The United States
DEPARTMENT TX
The United States
The United States
DEPARTMENT
Portugal
INTERIOR
Ukraine
DEFENSE
Shop with Confidence
FAQs
Have a Question?
-
Are there any agency discounts offered?
Yes, please contact our sales department for agency discounts, whether for an individual or agency wide.
-
What is the standard lead time?
1-3 business days upon payment receipt.