About this product
Industrial-Grade Mobile Decon for HAZMAT, Emergency Response & Military Operations
Deploy the DS-1 anywhere a fast, reliable decontamination capability is needed—Toxic Industrial Chemicals (TICs), Chemical Warfare Agents (CWAs), biological contaminants, radiological particulates, or unknown CBRN threats. Use it for personnel in PPE or direct full-body decontamination in remote or disaster-stricken zones.
Why Choose the DS-1 Over Fixed or Temporary Systems?
-
Unmatched Mobility: Total system ~152 lbs (69 kg)
- Shower: 88 lbs (40 kg)
- Decontamination box: 64 lbs (29 kg)
- Rapid Deployment: Fully operational in < 60 minutes. No construction or permanent plumbing required.
- All-Weather Resilience: Tented roof prevents rain pooling; integrated basin manages wastewater.
- Continuous Operation: Built with industrial-grade components for sustained use.
- Pallet Shipping Required: Specialized, multi-component system ships on a pallet.
Key Features — Engineered for Life-Saving Efficiency
Instant Inflation Technology
- Single-valve, rapid inflation (≈ < 60 seconds), with pressure safety valve.
- Durable enclosure:
- Inflated: 78.74" L × 78.74" W × 96.45" H (200 × 200 × 245 cm)
- Packed: 43.3" L × 31.5" W × 13.78" H (110 × 80 × 35 cm)
- Packed Size (quick reference): Shower ≈ 3′ × 4′ × 1′; Decon box ≈ 2′ × 1′ × 2′
Precision Decontamination Coverage
- 5 fixed nozzles + 1 wall-mounted hand shower deliver 360° body/suit coverage.
- External assist sleeves allow an operator to run the hand shower from outside the unit.
- Clear viewing windows provide maximum lighting and visibility for assisted decontamination.
Industrial Pump System
WPS 5.2 Pump (Cleaning)
- Flow: 19 L/min
- Continuous runtime: up to 20 minutes
- Inputs: 3/8" BSP, 1/2" hoses
- Maximum suction height: 3 m
- Motor: 185 W
- Switch pressure: 3.7 bar
- Cut-off pressure: 5 bar
- Max liquid temperature: 50 °C (122 °F)
WPS 2.4 Pump (Drainage via suction bucket)
Flow: 9 L/min
Continuous runtime: up to 20 minutes
Inputs: 3/8" BSP, 1/2" hoses
Maximum suction height: 2 m
Motor: 87 W
Temperature Envelope: Ambient operation up to 60 °C (140 °F); pump liquid temperature limit 50 °C (122 °F).
Simplified Command & Control
- Intuitive 3-switch interface, operable while wearing full PPE.
- Power: 220 V / 24 V / 300 W (generator or inverter-ready).
Integrated Waste Management
- Pre-routed lines to two 120-liter barrels (cleaning solution & wastewater).
- Built-in drainage basin prevents hazardous pooling; continuous 9 L/min waste extraction.
Field-Ready Durability
- Repair kit + 4 patches included for in-field maintenance.
- 5-year warranty for long-term serviceability.
Technical Specifications
Decontamination Shower (Enclosure)
| Parameter | Specification |
|---|---|
| Inflated dimensions | 78.74" L × 78.74" W × 96.45" H (200 × 200 × 245 cm) |
| Packed dimensions | 43.3" L × 31.5" W × 13.78" H (110 × 80 × 35 cm) |
| Packed size (quick reference) | Shower ≈ 3′ × 4′ × 1′; Decon box ≈ 2′ × 1′ × 2′ |
| Weight | 88.18 lbs (≈ 40 kg) |
| Design | Tented roof; clear windows; integrated sleeves; drainage basin |
Pumps & Flow
| Component | Details |
|---|---|
| WPS 5.2 (Cleaning) | Flow: 19 L/min; Continuous runtime: up to 20 min; Inputs: 3/8" BSP & 1/2" hoses; Max suction height: 3 m; Motor: 185 W; Switch pressure: 3.7 bar; Cut-off pressure: 5 bar; Max liquid temp: 50 °C (122 °F) |
| WPS 2.4 (Drainage) | Flow: 9 L/min; Continuous runtime: up to 20 min; Inputs: 3/8" BSP & 1/2" hoses; Max suction height: 2 m; Motor: 87 W |
Decontamination Control Box
| Parameter | Specification |
|---|---|
| Dimensions | 22.4" L × 16" W × 24" H (57 × 41 × 61 cm) |
| Weight | 64 lbs (≈ 29 kg) |
| Power | 220 V / 24 V / 300 W |
| Interface | 3 main switches, glove-friendly |
System Totals
| Parameter | Specification |
|---|---|
| Estimated total weight | ~152 lbs (69 kg) |
| Max ambient temperature | 60 °C (140 °F) |
| Max liquid temperature (pumps) | 50 °C (122 °F) |
| Runtime per cycle | ~20 minutes (continuous) |
What’s Included
- Inflatable shower enclosure
- Decontamination control box with built-in pumps
- Portable air compressor
- Two (2) × 120-liter barrels (clean solution & wastewater), pre-routed for hoses/pump gear
- Hose set
- Repair kit with four patches
Operational Flexibility — Who Relies on the DS-1?
- Firefighters & HAZMAT Teams: On-scene mass-casualty decon
- Military & CBRN Units: Forward operating base support and rapid setup
- Police/SWAT: Post-riot or clandestine lab exposure mitigation
- Industrial Sites: Refinery/factory/lab emergency response
- Hospitals & Clinics: Isolation unit/ER decontamination workflows
Best Practice: Pair with the MIRA Safety Basic Decontamination System for a two-step, thorough cleaning protocol.
Storage & Safety Compliance
- Storage environment: Dark, cool, dust-free; 5 °C to 25 °C (41 °F to 77 °F); ≤ 60% RH; regularly ventilated; avoid sudden temperature changes.
- Keep away from: Radiant heat/sunlight, fuels, solvents, lubricants, and other flammables.
- Generator safety: Never operate generators in enclosed spaces (risk of toxic exhaust accumulation).
Ordering & Logistics
- Shipping: Pallet required (specialized, multi-component system).
- Condition: Ships complete and field-test validated.
- Warranty: 5 years.
Deploy Confidence. Defeat Contamination.
The MIRA Safety DS-1 delivers a robust, mobile decontamination capability where fixed systems aren’t feasible and time is critical. Trusted by global response units. Engineered for the unthinkable.
Deployed by:
The United States
DEFENSE
The United States
HOMELAND SECURITY
The United States
BORDER PROTECTION
The United States
GUARD
The United States
CORRECTIONS
The United States
DEPARTMENT TX
The United States
The United States
DEPARTMENT
Portugal
INTERIOR
Ukraine
DEFENSE
Shop with Confidence
FAQs
Have a Question?
-
Are there any agency discounts offered?
Yes, please contact our sales department for agency discounts, whether for an individual or agency wide.
-
What is the standard lead time?
1-3 business days upon payment receipt.